| Sign In | Join Free | My bjjsgy.com | 
 | 
Brand Name : VICTOR
Model Number : VICTOR 26H
Certification : CE
Place of Origin : CHINA
MOQ : 1pcs
Price : USD1550/pc
Payment Terms : T/T, Western Union, L/C, Paypal
Supply Ability : 1000pcs available
Delivery Time : 5 to 30 days
Packaging Details : 6pcs/Carton; Carton Size: 53*40.5*31cm
Color : Blue and Black
Size : 206 × 97× 60 mm
Product Name : Multifunction Process Calibrator
Model No. : VICTOR 26
Packing Details : 6pcs/Carton; Carton Size: 53*40.5*31cm
Accuracy : 0.01% accuracy
Weight : Approx. 633g (including batteries)
Protection : IP65
Communication : HART
24 Volt Loop Circuit IP65 Multifunction Process Calibrator 5 Digits Display
VICTOR26H Multifunction Process Calibrator HARTCommunication With Accuracy 0.01% 5 Digits Display 24V loop circuit IP65
Multifunction Process Calibrator with HART Communication
Statement: this is applied to both HART type and Basic type multifunction process calibrators. Illustrations concerned with HART operations can be applied only to HART type. All explanations and examples are made on HART type.
1. Introduction
Multifunction process calibrator (as the Calibrator for short) is a hand-hold portable calibrator powered by batteries / Adapter, and can measure and source electrical paracalibrators and physical paracalibrators (See Table 1).
Table 1. List for Source and Measurement Functions
| Measurement Functions 
 Source Functions | DCV | DCI | OHM | FREQ | TC | RTD | PULSE | PRESSURE | CONTACT | ||
| LOOP OFF | LOOP ON | ||||||||||
| DCV | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| DCI | ------ | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | 
| RAMP ON | × | × | × | × | × | × | × | × | × | × | |
| AUTO STEP ON | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| OHM | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| FREQ | ● | ● | ● | ● | × | ● | ● | × | × | ● | |
| PULSE | ● | ● | ● | ● | × | ● | ● | × | × | ● | |
| CONTACT | ● | ● | ● | ● | × | ● | ● | × | × | ● | |
| TC | ● | ● | ● | ● | ● | × | × | ● | ● | ● | |
| RTD | ● | ● | ● | ● | ● | × | × | ● | ● | ● | |
| PRESSURE | ● | ● | ● | ● | × | ● | ● | × | × | ● | |
The Calibrator processes the following features expect the above-mentioned:
§ Any function state can enter into HART function directly (only for HART type)
§ Measurement and sourcing can work simultaneously. Measured information and soured information display separately
§ Thermal couple (TC) input/output terminals and the internal process automatic temperature compensation reference node
§ Manual step sourcing, auto step and ramp current sourcing
§ Indoor temperature monitor in any operation
§ Measurement/ output temperature monitor function
§ Measurement/ sourcing mA% display
§ Measurement filtering function
§ Measurement manual hold function
§ Auto-hold function of sourced pressure value display
2. Standard Accessories
Make sure that the package contains all the accessories listed below. And if you find they are damaged or any of them is missing, please contact the vendor from which you purchased the product as soon as possible. Refer to the replacing part list in 15.3 in the Manual if you want to order the replacing parts.
§ One pair of Testing Probe(H000000-00)
§ One pair of Industrial testing Lead(H000001-00)
§ One pair of Industrial testing Lead (H000002-00)
§ One pair of hook Testing Probe (H000004-00)
§ One pair of Alligator clip(H010000-00)
§ One pair of Alligator clip(H010007-00)
§ One set of RTD Convertor(H200000-00)
§ One copy of A User's Manual
§ One copy of Certification of Warranty
§ Two pieces of Fuse Tube(100mA/250V)
§ Two pieces of Fuse Tube(50mA/250V)
§ Four alkaline batteries
One Bag
| Project | Model Performance parameters | VICTOR 26 | VICTOR 26H | |
| Source | DC millivolt | Range | -5 ~ 110mV | -5 ~ 110mV | 
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uV | 1uV | ||
| DC voltage | Range | -1 ~ 11V | -1 ~ 11V | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 10uV/0.1mV | 10uV/0.1mV | ||
| DC current | Range | 0 ~ 33mA | 0 ~ 33mA | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uA | 1uA | ||
| Sink current | Range | 0 ~ 33mA | 0 ~ 33mA | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uA | 1uA | ||
| External power supply | 5 ~ 28V | 5 ~ 28V | ||
| Resistance | Range | 0 ~4KΩ | 0 ~4KΩ | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 0.01Ω/0.1Ω | 0.01Ω/0.1Ω | ||
| Thermocouple | Range | R/S/K/E/J/T/B/N/L/U | R/S/K/E/J/T/B/N/L/U | |
| Accuracy | 0.4℃ | 0.4℃ | ||
| Resolution | 0.1℃/1℃ | 0.1℃/1℃ | ||
| RTD | Range | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | |
| Accuracy | 0.2℃ | 0.2℃ | ||
| Resolution | 0.1℃ | 0.1℃ | ||
| Frequency (Hz) | Range | 1Hz ~110KHz | 1Hz ~110KHz | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | 0.01Hz/1Hz/0.1KHz/2KHz | ||
| Frequency(CMP) | Range | 60~1200 CPM | 60~1200 CPM | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 1CPM | 1CPM | ||
| Pulse | Frequency | 1Hz ~10KHz | 1Hz ~10KHz | |
| Range | 1 ~100000cyc | 1 ~100000cyc | ||
| Accuracy | ±2words | ±2words | ||
| Resolution | 1cyc | 1cyc | ||
| Switch | Range | 1Hz ~110KHz | 1Hz ~110KHz | |
| Accuracy | ±2 | ±2 | ||
| Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | 0.01Hz/1Hz/0.1KHz/2KHz | ||
| Pressure | Range | Depends on the pressure module | Depends on the pressure module | |
| Accuracy= ±(% of the set value+% of range) | Depends on the pressure module | Depends on the pressure module | ||
| Resolution | 5 digit display | 5 digit display | ||
| Measurement | DC millivolt | Range | -5 ~ 550mV | -5 ~ 550mV | 
| Accuracy= ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uV/10uV | 1uV/10uV | ||
| DC voltage | Range | -0.5 ~ 35V | -0.5 ~ 35V | |
| Accuracy= ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 0.1mV/1mV | 0.1mV/1mV | ||
| DC current | Range | -5 ~ 55mA | -5 ~ 55mA | |
| Accuracy ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uA | 1uA | ||
| Resistance | Range | 0 ~5.5KΩ | 0 ~5.5KΩ | |
| Accuracy= ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 0.01Ω/0.1Ω | 0.01Ω/0.1Ω | ||
| Thermocouple | Range | R/S/K/E/J/T/B/N/L/U | R/S/K/E/J/T/B/N/L/U | |
| Accuracy | 0.7℃ | 0.7℃ | ||
| Resolution | 0.1℃/1℃ | 0.1℃/1℃ | ||
| RTD | Range | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | |
| Accuracy | 0.4℃ | 0.4℃ | ||
| Resolution | 0.1℃ | 0.1℃ | ||
| Frequency (Hz) | Range | 3Hz ~50KHz | 3Hz ~50KHz | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 0.01Hz | 0.01Hz | ||
| Frequency(CMP) | Range | 180~3000000 CPM | 180~3000000 CPM | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 1CPM | 1CPM | ||
| Switch | Range | CLOSE/OPEN | CLOSE/OPEN | |
| Threshold | 200 ~300Ω | 200 ~300Ω | ||
| Pressure | Range | Depends on the pressure module | Depends on the pressure module | |
| Accuracy= ±( % of Reading+ % of Range) | Depends on the pressure module | Depends on the pressure module | ||
| Resolution | 5 digit display | 5 digit display | ||
| Continuity beeper | Range | 0 ~500Ω | 0 ~500Ω | |
| Accuracy | ≤50Ωsound | ≤50Ωsound | ||
| Resolution | 0.01Ω | 0.01Ω | ||
| Loop power supply | Range | 24V | 24V | |
| Accuracy | ±10% | ±10% | ||
| The maximum current | 22mA | 22mA | ||
| HART | × | √ | ||
| Other functions | Backlight | √ | √ | |
| Auto Power-off | √ | √ | ||
| Charging function | √ | √ | ||
| Room temperature display | √ | √ | ||
| Battery detection | √ | √ | ||
| The ramp signal | √ | √ | ||
| Communication function | RS232 serial communication, can realize remote control instrument by the device driver software. | RS232 serial communication, can realize remote control instrument by the device driver software. | ||
| Characteristic | ||||
| Safety | EN61010-1:2001 | EN61010-1:2001 | ||
| Withstand voltage | The input and output AC350V/1 minutes | The input and output AC350V/1 minutes | ||
| Insulation | The input and output DC500V /50MΩ. | The input and output DC500V /50MΩ. | ||
| EMC | EN61326-1:2006 | EN61326-1:2006 | ||
| Authentication | CE | CE | ||
| Display | 3.2“ TFT screen | 3.2“ TFT screen | ||
| Power supply | 4×1.5V AA Alkaline battery | 4×1.5V AA Alkaline battery | ||
| Size | 206 × 97 × 60 mm | 206 × 97 × 60 mm | ||
| Weight | about 633g | about 633g | ||
| Standard Quantity Per Carton | 6pcs | 6pcs | ||
| Standard Carton Measurement | 530mm*405mm*310mm | 530mm*405mm*310mm | ||
| Standard Carton Cross Weight | 12.6kg | 12.6kg | ||











|   | 
| 24 Volt Loop Circuit IP65 Multifunction Process Calibrator 5 Digits Display Images | 
 2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                                                    
                        
                        
                        
                                                            2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                    
                        
                     100MV Digital Signal Generator Analog Transmitter Source Simulator
                                                                                    
                        
                        
                        
                                                            100MV Digital Signal Generator Analog Transmitter Source Simulator
                                                    
                        
                     VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator
                                                                                    
                        
                        
                        
                                                            VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator
                                                    
                        
                     VICTOR 06 V/mA calibrator measure DCV DCA simulating output DC voltage, DC
                                                                                    
                        
                        
                        
                                                            VICTOR 06 V/mA calibrator measure DCV DCA simulating output DC voltage, DC
                                                    
                        
                     VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple
                                                                                    
                        
                        
                        
                                                            VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple
                                                    
                        
                     VICTOR 01S Temperature Signal Generator Temperature Source process calibrator
                                                                                    
                        
                        
                        
                                                            VICTOR 01S Temperature Signal Generator Temperature Source process calibrator
                                                    
                        
                     VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument
                                                                                    
                        
                        
                        
                                                            VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument
                                                    
                        
                     RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
                                                                                    
                        
                        
                        
                                                            RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
                                                    
                        
                     VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator
                                                                                    
                        
                        
                        
                                                            VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator
                                                    
                        
                     High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator
                                                                                    
                        
                        
                        
                                                            High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator